HI7061L is a general-purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty during use, producing inaccurate results.

Solution de nettoyage pour électrodes, usage général, bouteille 500 mL HI7061L HANNA
search
  • Solution de nettoyage pour électrodes, usage général, bouteille 500 mL HI7061L HANNA
Solution de nettoyage pour électrodes, usage général, bouteille 500 mL HI7061L HANNA
In stock - Dispatched within 24 hours
€20.75
Quantity
1 Item

In stock - Dispatched within 24 hours

attach_money By buying this product you can collect up to 20 loyalty points. Your cart will total 20 points that can be converted into a voucher of 0.40 €.

Data sheet

Dangerous classified products Article R. 1342-1:
Dangerous. Follow the usage precautions.

En savoir plus

Cleaning solution for electrodes, general use, 500 mL bottle HI7061L HANNA

Description

HI7061L is a general-purpose cleaning solution that can be used for a variety of applications. Electrodes can get dirty during use, resulting in inaccurate readings. Cleaning solutions Hanna eliminate impurities and residues on the surface of the electrode, which form during measurement or when it is not stored properly. It is advisable to regularly clean the bulb and the porous septum of the electrode to prevent blockages and obtain accurate measurements.

Information

The most common cause of inaccurate pH measurements is a dirty or improperly cleaned electrode. This is very important because during calibration, the instrument assumes that the electrode is clean and that the calibration curve created during calibration will remain a valid reference until the next calibration. The pH meters available on the market today have an offset value of approximately ± 60 mV, with a deviation not exceeding ± 30 mV. Calibration compensates for the change in the offset value. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode, the readings will be inaccurate.

Characteristics

- Cleaning solution for pH electrodes

- Sealed bottle that guarantees quality

- Expiration date and batch number

- Sealed bottle -It guarantees the quality and freshness of the solution.

- Lot number and expiration date on each vial - Cleaning solutions Hanna retain their pH if the bottle is not opened.

Recommendations

Cleaning is a quick and effective procedure that should be performed regularly to avoid using a dirty electrode and to prevent the porous septum from becoming clogged. Soak the electrode in the HI7061L cleaning solution for 15 to 20 minutes to remove deposits or coatings.

Technical specifications

Description General-purpose cleaning solution
Certificate of Analysis no
Packaging vial
Quantity 1
The volume 500 ml