Hanna Marine Master Multi-Parameter 2023 HI97115

The new HI97115 "Marine Master" photometer is a true mini-laboratory for essential analyses in aquaristics and marine biology.
It allows precise monitoring of 8 essential parameters for the well-being of marine biotope inhabitants.

Hanna Marine Master multi paramètres 2023 HI97115
search
  • Hanna Marine Master multi paramètres 2023 HI97115
Hanna Marine Master multi paramètres 2023 HI97115
In stock - Dispatched within 24 hours
€456.00
Quantity
1 Item

In stock - Dispatched within 24 hours

attach_money By buying this product you can collect up to 456 loyalty points. Your cart will total 456 points that can be converted into a voucher of 9.12 €.

Data sheet

Dangerous classified products Article R. 1342-1:
Dangerous. Follow the usage precautions.

En savoir plus

The new HI97115 "Marine Master" photometer is a true mini-laboratory for essential analyses in aquariums and marine biology. It allows precise monitoring of 8 vital parameters for the well-being of marine biotope inhabitants. The HI97115 can be used as a portable photometer for routine spot measurements and can be connected to the application Hanna Lab App with a smart device compatible via the integrated Bluetooth module. When connected, Hanna Lab App stores measurements with extended storage capacity, allows for adding observations, data sharing, as well as the creation and storage of method groups.

  • Advanced optical system with LED light source, ensuring high measurement accuracy: IP67 waterproof, lightweight and portable, floats on water in case of accidental drop.
  • Very economical cost per test
  • Tutorial mode on the screen, indicating step by step each stage of the measurement procedure for each parameter
  • Memory capacity for 200 measurements, with the possibility of associating them with up to 10 tanks or sampling locations.
  • Direct readings in mg/L, μg/L, and pH
  • Bluetooth connectivity for data transfer and backup on a smartphone or tablet

1. PRELIMINARY EXAMINATION


Unpack the instrument and its accessories and examine them carefully to ensure that no damage occurred during transport. If you notice any deterioration, contact Hanna Instruments ®.

Wavelength Parameter Range Resolution Accuracy at 25 °C

The Reagents are not provided.

Here are the references for the articles to conduct the tests:

 

- Alkalinity 610 nm 0.6 to 20.0 dKH 0.1 dKH ±0.3 dKH ± 5% of reading HI772-26 (25 tests)

- Ammonia (NH3) 610 nm 0.10 to 2.50 mg/L 0.01 mg/L ±0.05 mg/L ± 5% of the reading HI784-25 (25 tests)

- Calcium 610 nm 200 to 600 mg/L 1 mg/L ±6% of the reading HI758-26 (25 tests)

- Magnesium (Mg2+) 610 nm 1000 to 1800 mg/L 5 mg/L ±5% of the reading HI783-25 (25 tests)

- Nitrates narrow range (NO3 ¯) 525 nm 0.50 to 5.00 mg/L 0.01 mg/L ±0.25 mg/L ± 2% of reading HI740273+ HI781-25 (25 tests)

- Nitrates wide range (NO3 ¯ ) 525 nm 4.0 - 75.0 mg/L 0.1 mg/L ±2.0 mg/L ± 5% of the reading HI782-25 (25 tests)

- Nitrites, traces (NO2 ¯ -N) 525 nm 20 to 200 µg/L 1 µg/L ±10 µg/L ±4% of reading HI764-25 (25 tests)

- pH 525 nm 6.3 - 8.6 pH 0.1 pH ±0.2 pH HI780-25 (100 tests)

- Phosphates, traces 610 nm 0.04 to 0.90 mg/L 0.01 mg/L ±0.02 mg/L ± 5% of the reading HI774-25 (25 tests)

2. SAFETY MEASURES

• The chemicals contained in the reagent kits can be hazardous if not handled properly.
• Read the safety data sheets (SDS) before conducting the tests.
• Safety equipment: Wear eye protection and appropriate clothing if necessary, and carefully follow the instructions.
• Spill of reagents: In case of reagent spills, wipe immediately and rinse thoroughly with water. In case of skin contact, rinse
Carefully wash the affected area with water. Avoid inhaling the fumes.
• Waste disposal For the proper disposal of reagent kits and reacted samples, contact a licensed waste disposal service provider.


3. ABBREVIATIONS

dKH Carbonate Hardness Degree
EPA U.S. Environmental Protection Agency
HDPE High-Density Polyethylene
GH High range
LED Light Emitting Diode
GB Low range
mg/L Milligrams per liter (ppm)
NIST National Institute of Standards and Technology
ppb Part per billion
ppm stands for "Part per million".
EDOI Demineralized water by reverse osmosis
GUB Ultra Low Range
μg/L Micrograms per liter (ppb)


4. SPECIFICATIONS

Specifications HI97115

LED light source

Bowl type: Round bowl Ø 24.6 mm (Ø 22 mm inside)

Environment 0 to 50°C, max RH 95%

Memorization of 200 measurements, identification of 10 sampling locations.

Powered by 3 AA 1.5 V batteries, 800 measurements (without backlight)

Automatic shutdown after 15 minutes of non-use

Dimensions: 142.5 x 102.5 x 50.5 mm

Weight 380 g

Colorimetric method
The reaction produces a range of distinct colors.
ranging from yellow to blue-green.

LED 610 nm
Calcium, seawater
Range 200 to 600 ppm
Resolution 1 ppm
Accuracy ±6% of the reading
Method Adaptation of the Zincon Method
LED 610 nm
Nitrates GB, seawater
Range 0.00 to 5.00 ppm (NO3-)
Resolution 0.01 ppm
Accuracy ±0.25 ppm ±2% of the reading
  

WARRANTY

HI97115 is guaranteed for two years against manufacturing and material defects.
"when used for their intended purposes and maintained according to the instructions."
This warranty is limited to repair or replacement at no charge. The
damage resulting from accidents, misuse, alteration, or
from a lack of recommended maintenance are not covered.
If a repair is necessary, contact Hanna Instruments. If the instrument is
under warranty, indicate the reference of the instrument, the date of purchase (provide a
Copy of the invoice), the serial number, and the nature of the problem. If the repair
is not covered by the warranty, you will be informed of the incurred costs. When
If you are shipping an instrument, make sure it is properly packaged to ensure a
to avoid deterioration during transport.

Hanna Instruments reserves the right to modify the design, manufacturing, or appearance of its products without notice.

 

You might also like