- Out-of-Stock
Hanna Marine Master Multiparameter Kit 2023 HI97115C
The new HI97115 "Marine Master" photometer is a true mini-laboratory for essential aquarium and marine biology analyses.
It allows precise monitoring of 8 essential parameters for the well-being of the inhabitants of marine biotopes.
Data sheet
- Dangerous classified products Article R. 1342-1:
- Dangerous. Follow the usage precautions.
En savoir plus
The new HI97115C "Marine Master" photometer is a true mini-laboratory for essential analyses in aquariology and marine biology. It allows for precise monitoring of 8 essential parameters for the well-being of marine biotope inhabitants. HI97115 can be used as a portable photometer for routine spot measurements and can be connected to the application. Hanna Lab App with a smart device compatible via the integrated Bluetooth module. When connected, Hanna Lab App stores measurements with extended storage capacity, allows adding observations, data sharing, as well as the creation and storage of method groups.
- Advanced optical system with LED light source, ensuring high measurement accuracy: IP67 waterproof, lightweight and portable, floats on water in case of accidental drop.
- Very economical cost per test
- Tutorial mode on the screen, indicating step by step each stage of the measurement procedure for each parameter.
- Memory for 200 measurements, with the possibility to associate them with up to 10 tanks or sampling locations.
- Direct readings in mg/L, μg/L, and pH
- Bluetooth connectivity for data transfer and backup on a smartphone or tablet
1. PRELIMINARY EXAMINATION
Unpack the instrument and its accessories and examine them carefully to ensure no damage occurred during transport. If you notice any deterioration, contact Hanna Instruments ®.
Parameter Wavelength Range Resolution Accuracy at 25°C
The reagents are provided with the kit.
Here are the references for the solutions provided in the kit to carry out your tests:
- Alkalinity 610 nm 0.6 to 20.0 dKH 0.1 dKH ±0.3 dKH ± 5% of the reading HI772-26 (25 tests)
- Ammonia (NH3) 610 nm 0.10 to 2.50 mg/L 0.01 mg/L ±0.05 mg/L ± 5% of the reading HI784-25 (25 tests)
- Calcium 610 nm 200 to 600 mg/L 1 mg/L ±6% of the reading HI758-26 (25 tests)
- Magnesium (Mg2+) 610 nm 1000 to 1800 mg/L 5 mg/L ±5% of the reading HI783-25 (25 tests)
- Nitrates narrow range (NO3 ¯ ) 525 nm 0.50 to 5.00 mg/L 0.01 mg/L ±0.25 mg/L ± 2% of the reading HI740273+ HI781-25 (25 tests)
- Nitrates wide range (NO3 ¯) 525 nm 4.0 - 75.0 mg/L 0.1 mg/L ±2.0 mg/L ± 5% of the reading HI782-25 (25 tests)
- Nitrites, traces (NO2 ¯ -N) 525 nm 20 to 200 µg/L 1 µg/L ±10 µg/L ±4% of the reading HI764-25 (25 tests)
- pH 525 nm 6.3 - 8.6 pH 0.1 pH ±0.2 pH HI780-25 (100 tests)
- Phosphates, traces 610 nm 0.04 to 0.90 mg/L 0.01 mg/L ±0.02 mg/L ± 5% of the reading HI774-25 (25 tests)
2. SAFETY MEASURES
• The chemicals contained in the reagent kits can be hazardous if they are not handled properly.
• Read the safety data sheets (SDS) before carrying out the tests.
• Safety equipment: Wear eye protection and appropriate clothing if necessary, and carefully follow the instructions.
• Reagent Spill In case of a reagent spill, wipe immediately and rinse thoroughly with water. If it comes into contact with skin, rinse.
Carefully rinse the affected area with water. Avoid inhaling the vapors released.
• Waste Disposal For the proper disposal of reagent kits and reacted samples, contact a licensed waste disposal service provider.
3. ABBREVIATIONS
dKH Carbonate Hardness Degree
EPA United States Environmental Protection Agency
HDPE High-Density Polyethylene
GH High-end range
LED Light-emitting diode
GB Low range
mg/L Milligrams per liter (ppm)
NIST National Institute of Standards and Technology
ppb Part per billion
ppm Parts per million
EDOI Demineralized water by reverse osmosis
GUB Ultra Low Range
μg/L Micrograms per liter (ppb)
4. SPECIFICATIONS
Specifications HI97115C
LED light source
Type of bowl: Round bowl Ø 24.6 mm (Ø 22 mm interior)
Environment 0 to 50°C, max RH 95%
Memorization of 200 measurements, identification of 10 sampling locations
Power supply: 3 AA 1.5V batteries, 800 measurements (without backlight)
Auto shut-off after 15 minutes of non-use
Dimensions 142.5 x 102.5 x 50.5 mm
Weight 380 g
Colorimetric method
The reaction produces a range of distinct colors.
ranging from yellow to blue-green.
LED 610 nm
Calcium, seawater
Range 200 to 600 ppm
Resolution 1 ppm
Accuracy ±6% of the reading
Method Adaptation of the Zincon method
LED 610 nm
Nitrates GB, seawater
Range 0.00 to 5.00 ppm (NO3-)
Resolution 0.01 ppm
Accuracy ±0.25 ppm ±2% of the reading
WARRANTY
HI97115 is guaranteed for two years against manufacturing and material defects.
"when used for their intended purposes and maintained according to the instructions."
This warranty is limited to repair or replacement at no cost. The
damage resulting from accidents, misuse, alteration, or
"Lack of recommended maintenance is not covered."
If a repair is necessary, contact Hanna Instruments. If the instrument is
under warranty, indicate the reference of the instrument, the date of purchase (provide a
copy of the invoice), the serial number, and the nature of the problem. If the repair
is not covered by the warranty, you will be informed of the incurred costs. When
If you are shipping an instrument, make sure it is properly packaged for shipping.
avoid deterioration during transport.
Hanna Instruments reserves the right to modify the design, manufacturing, or appearance of its products without notice.